Q1: How do you perform pressure drop testing for fiber bed mist eliminators?
A: At Filtearth, every fiber bed mist eliminator undergoes factory differential pressure testing under simulated process gas flow conditions. We measure the dry pressure drop and calculate the operating wet pressure drop based on liquid loading rates and gas velocity, ensuring optimal balance between continuous filtration efficiency (>99.9%) and overall fan energy consumption.
Q3: Which materials are suitable for fiber bed mist eliminators in corrosive acid environments?
A: Mesh pad demisters rely on inertial impaction and are suitable for removing large droplets (> 5–10 microns). In contrast, Filtearth fiber bed mist eliminators utilize Brownian diffusion principles, allowing them to capture submicron aerosol particles (< 1 micron) with over 99.9% collection efficiency, making them ideal for high-efficiency sulfuric acid and chlor-alkali applications.
Q3: Which materials are suitable for fiber bed mist eliminators in corrosive acid environments?
A: For aggressive chemical environments, Filtearth offers customized material configurations including Special Glass Fiber, PTFE, and Polypropylene (PP) filter media, supported by corrosion-resistant cages made of Stainless Steel 316L, 904L, Titanium Alloys, or FRP/PP structures.